Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 40A Contactor 2-Pole 24V Coil for CH16NA04800GBAAA
Carrier

OEM Carrier 40A Contactor 2-Pole 24V Coil for CH16NA04800GBAAA

SKU: CARRIE-CH16NA04800GBAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit CH16NA04800GBAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model CH16NA04800GBAAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Carrier CH16NA04800GBAAA split-system condenser. The contactor is a high-voltage relay that receives a 24V signal from your thermostat and closes to deliver line voltage to the compressor and condenser fan motor. When a contactor fails — due to burned or pitted contact points, a stuck plunger, or a failed coil — the outdoor unit will not energize at all, or may run continuously without shutting off. Replacing the contactor is one of the most common and cost-effective AC repairs available.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp rated | Direct OEM replacement — matches factory wiring, mounting footprint, and terminal layout for the CH16NA04800GBAAA
  • OEM vs Generic: OEM contactors use silver-alloy contact tips rated for thousands of switching cycles. Generic aftermarket contactors often use lower-grade contacts that pit and weld faster, leading to repeat failures and potential compressor damage from voltage drop.
  • Install difficulty: 3/5 — Requires shutting off power at the disconnect AND the breaker panel before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, and insulated gloves. Photograph all wiring before disconnecting. Swap one wire at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled warehouse.

Compatibility: Engineered specifically for the Carrier CH16NA04800GBAAA 4-ton split-system condenser. Verify coil voltage (24V) and pole configuration on your existing contactor's label before ordering. Our fitment team is available to confirm compatibility — reach out before you order if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier CH16NA04800GBAAA?
Yes. This is the factory-specified OEM contactor for the Carrier CH16NA04800GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier CH16NA04800GBAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR