OEM Carrier Pressure Switch High/Low for CH14NA06000GBBAA
Carrier

OEM Carrier Pressure Switch High/Low for CH14NA06000GBBAA

SKU: CARRIE-CH14NA06000GBBAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit CH14NA06000GBBAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch for Model CH14NA06000GBBAA

These OEM pressure switches — 312926-252 (High Pressure Switch) and 312926-258 (Low Pressure Switch) — are the factory-specified replacements for the Carrier CH14NA06000GBBAA condensing unit. Pressure switches monitor the inducer motor's draft pressure to confirm safe venting conditions before allowing the ignition sequence to proceed. When either switch fails or sticks open, the control board cannot verify proper airflow and will lock out the system entirely — leaving you with a furnace or heat pump that attempts to start but shuts down before any heat is produced. Common symptoms include a status code indicating pressure switch fault, an inducer motor running continuously with no ignition, or intermittent heating failures in cold or windy conditions.

  • Specs: Part 312926-252 — High Pressure Switch | Part 312926-258 — Low Pressure Switch | Factory W.C. (water column) rating matched to Carrier CH14NA06000GBBAA inducer assembly | SPST normally open contacts | 1/4" spade terminal connections
  • OEM vs Generic: OEM pressure switches are calibrated to the exact W.C. trip point required by this model. Aftermarket units frequently carry wider tolerances, risking nuisance lockouts or, more critically, allowing operation under unsafe venting conditions that could affect combustion safety.
  • Install difficulty: 3/5 — Requires shutting off power and gas supply before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, manometer (recommended to verify W.C. after install), and a multimeter to confirm switch continuity. Inspect rubber hose ports for cracks or blockages before installing new switch — a blocked port is a leading cause of switch failure.
  • Warranty: 1-year OEM factory warranty on both switches. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: Both 312926-252 and 312926-258 are designed specifically for the Carrier CH14NA06000GBBAA. Confirm which switch — high or low — has failed using your system's diagnostic fault code and a multimeter continuity test before ordering. If you are unsure which part applies to your repair, our HVAC parts specialists can verify fitment before you buy. Order today and get your system back online fast — in stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH14NA06000GBBAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH14NA06000GBBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH14NA06000GBBAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.