OEM Carrier High & Low Pressure Switch for Model CH13NA06000GACAA

These OEM pressure switches are the factory-specified replacements for the Carrier CH13NA06000GACAA condenser unit. Pressure switches are safety devices that monitor refrigerant pressure on both the high and low sides of the system. When either switch detects an out-of-range pressure condition — caused by low refrigerant, a blocked coil, or a failing compressor — it opens the control circuit and shuts the system down to prevent damage. Common symptoms of a failed pressure switch include the system locking out on startup, short-cycling, or displaying a fault code related to high or low pressure protection.

  • Specs: OEM Part 312926-252 (High Pressure Switch) | OEM Part 312926-258 (Low Pressure Switch) | 24V control circuit compatible | Factory-calibrated trip points for R-410A refrigerant systems
  • OEM vs Generic: OEM pressure switches are calibrated to exact factory trip-point specifications, ensuring reliable protection. Generic switches often use wider pressure tolerances that can allow unsafe operating conditions or cause nuisance lockouts.
  • Install Difficulty: 3/5 — Refrigerant system access required. A licensed HVAC technician should perform this repair. Tools needed: manifold gauge set, multimeter, adjustable wrench. Always recover refrigerant per EPA Section 608 regulations before replacing switches in the refrigerant circuit.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: Designed specifically for the Carrier CH13NA06000GACAA condenser. Verify OEM part numbers 312926-252 (high side) and 312926-258 (low side) against your unit's wiring diagram or existing switch label before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you buy — contact us today and get your system back up and running fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA06000GACAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA06000GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA06000GACAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online