OEM Carrier 2-Pole Contactor 24V Coil for Model CH13NA06000GACAA
This is the factory OEM replacement contactor (part number HN51JD026) for the Carrier CH13NA06000GACAA split-system air conditioner. The contactor is a high-voltage relay controlled by a 24V signal from the thermostat. When the thermostat calls for cooling, the contactor closes its contacts to deliver 240V power to the compressor and condenser fan motor. A failed contactor is one of the most common reasons an air conditioner won't turn on — symptoms include the outdoor unit not energizing, buzzing or chattering at the contactor, or pitted/burned contact points visible on inspection.
-
Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp rated contacts | Direct OEM replacement for part number HN51JD026 | Factory-spec contact material for long service life
-
OEM vs Generic: This OEM contactor meets Carrier's exact coil pull-in voltage and contact resistance specifications. Generic contactors may use lower-grade contact alloys that pit and burn faster, especially in high-cycle summer conditions — shortening service life significantly.
-
Install difficulty: 2/5 — Shut off power at both the disconnect and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removal. The contactor mounts in the outdoor unit's control compartment and typically involves four high-voltage load wires and two 24V coil wires.
-
Warranty: 1-year OEM factory warranty against defects. Orders placed before our daily cutoff ship the same business day from our climate-controlled warehouse.
Compatibility: Designed specifically for the Carrier CH13NA06000GACAA condensing unit. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — just reach out before placing your order.