OEM Carrier High & Low Pressure Switch for Model CH13NA04800GAAAA

These OEM pressure switches — 312926-252 (High Pressure Switch) and 312926-258 (Low Pressure Switch) — are the factory-specified replacements for the Carrier CH13NA04800GAAAA condenser unit. Pressure switches monitor refrigerant pressure on both the high and low sides of the refrigerant circuit, cutting power to the compressor if pressure falls outside safe operating limits. When either switch fails, the system will typically lock out immediately or refuse to start, protecting the compressor from catastrophic damage caused by low refrigerant, blockages, or overcharge conditions.

  • Specs: Part 312926-252 — High Side Pressure Switch | Part 312926-258 — Low Side Pressure Switch | Factory-calibrated trip points | Spade terminal connectors | Direct OEM replacement with no modifications required
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact trip-point specifications for the CH13NA04800GAAAA. Generic alternatives often carry wider tolerance thresholds, risking nuisance trips or — more dangerously — delayed shutoff that can damage the compressor.
  • Install Difficulty: 2/5 — Always recover refrigerant before replacing pressure switches on a live circuit. Tools needed: manifold gauge set, refrigerant recovery machine, adjustable wrench, and a multimeter to verify switch continuity. A certified HVAC technician is recommended for refrigerant-side repairs per EPA Section 608 regulations.
  • Warranty: 1-year OEM factory warranty on both switches. Orders ship same business day from our stocked warehouse — no waiting on back-ordered parts.

Compatibility: Both switches are engineered specifically for the Carrier CH13NA04800GAAAA 4-ton single-stage condenser. Verify the failed switch (high or low side) using your manifold gauges and a multimeter before ordering. If you're unsure which switch has failed, our team can help verify fitment and diagnosis before you complete your order. In stock and ready to ship today — get your system back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA04800GAAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA04800GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA04800GAAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online