OEM Carrier High & Low Pressure Switch for Model CH13NA03600GACBA

These OEM pressure switches — 312926-252 (High Pressure Switch) and 312926-258 (Low Pressure Switch) — are the factory-specified replacements for the Carrier CH13NA03600GACBA condenser unit. Pressure switches monitor refrigerant circuit pressures and protect the system by shutting it down when pressures fall outside safe operating ranges. A failed pressure switch commonly causes the unit to trip into lockout, refuse to start, or cycle off immediately after startup — even when refrigerant charge and refrigerant pressures are within normal range.

  • Specs: 312926-252 — High Pressure Switch, factory-calibrated cutout set point | 312926-258 — Low Pressure Switch, factory-calibrated cutout set point | Direct OEM replacement | Designed for R-410A refrigerant systems
  • OEM vs Generic: OEM pressure switches are calibrated to exact factory cutout and reset pressures. Generic alternatives frequently carry wider tolerances, risking nuisance trips or — worse — failing to protect the compressor during a true overpressure or low-charge event.
  • Install Difficulty: 3/5 — Refrigerant must be properly recovered before replacing pressure switches on a live system. Tools needed: manifold gauge set, adjustable wrench, multimeter, refrigerant recovery equipment. Always verify system pressure is equalized and power is disconnected before disconnecting switch leads or fittings.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier CH13NA03600GACBA 3-ton R-410A condenser. Always confirm OEM part numbers 312926-252 or 312926-258 against your unit's wiring diagram or data plate before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before every order — contact us today and we'll get the right part shipped to your door fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA03600GACBA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA03600GACBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA03600GACBA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.