Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High & Low Pressure Switch Set for CH13NA03100GAAAA
Carrier

OEM Carrier High & Low Pressure Switch Set for CH13NA03100GAAAA

SKU: CARRIE-CH13NA03100GAAAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit CH13NA03100GAAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Set for Model CH13NA03100GAAAA

This OEM-matched pressure switch set includes both the high pressure switch (312926-252) and the low pressure switch (312926-258) factory-specified for the Carrier CH13NA03100GAAAA packaged or split-system unit. Pressure switches prove that the inducer motor has established adequate draft before allowing the ignition sequence to proceed. A failed pressure switch causes the system to lock out before ignition — commonly misdiagnosed as an igniter or control board fault. Symptoms include a running inducer with no spark, a flashing fault code for "pressure switch stuck open," or intermittent no-heat calls that seem to resolve on their own.

  • Specs: High Pressure Switch — OEM Part 312926-252 | Low Pressure Switch — OEM Part 312926-258 | Factory-calibrated W.C. (water column) rating | Single-pole, normally open contacts | 1/4" spade terminal connectors
  • OEM vs Generic: OEM pressure switches are calibrated to exact water-column specifications for the Carrier CH13NA03100GAAAA. Off-brand substitutes often carry wider tolerance ranges, leading to nuisance lockouts or — more dangerously — failure to detect a true draft problem, creating a carbon monoxide risk.
  • Install Difficulty: 2/5 — Power down and disconnect the unit before beginning. Tools needed: 1/4" nut driver, flat-head screwdriver, manometer (to verify W.C. rating post-install), and needle-nose pliers. Photograph hose routing and wiring before disconnecting. Inspect rubber pressure tubing for cracks or blockages while the switch is out — a blocked hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty on both switches. Orders ship same business day from our warehouse when placed before 3 PM local time.

Compatibility: This set is factory-matched to the Carrier CH13NA03100GAAAA. Always confirm both OEM part numbers (312926-252 and 312926-258) against your unit's wiring diagram or data plate before ordering. If you are only replacing one switch, each part is also available individually. Not sure which switch failed? Our HVAC parts team can help verify fitment and diagnose which switch to replace — contact us before you order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA03100GAAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA03100GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA03100GAAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online