OEM Carrier High & Low Pressure Switch for Model CH13NA03000GAABA

These OEM pressure switches — 312926-252 (High Pressure Switch) and 312926-258 (Low Pressure Switch) — are the factory-specified replacements for the Carrier CH13NA03000GAABA split-system condenser. Pressure switches monitor refrigerant pressure on both the high and low sides of the refrigerant circuit, cutting power to the compressor if pressures fall outside safe operating limits. When either switch fails, the system will typically trip into lockout, short-cycle, or refuse to start altogether, protecting the compressor from catastrophic damage.

  • Specs: High Pressure Switch — OEM Part# 312926-252 | Low Pressure Switch — OEM Part# 312926-258 | Factory-calibrated trip points | Direct plug-in wiring connectors for drop-in replacement
  • OEM vs Generic: OEM pressure switches are calibrated to the exact trip and reset pressures specified by Carrier engineering. Aftermarket substitutes often use wider tolerances that can allow unsafe pressures to go undetected, risking compressor failure and voiding equipment warranties.
  • Install Difficulty: 3/5 — Refrigerant circuit work requires an EPA 608-certified technician. Tools needed: manifold gauge set, multimeter, flat-head and Phillips screwdrivers. Always recover refrigerant before disconnecting pressure switch lines, and photograph all wiring before removal.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed specifically for the Carrier CH13NA03000GAABA 3-ton split-system condenser. Verify the failed switch (high-side or low-side) with a multimeter before ordering — both part numbers are listed above. If uncertain which switch has failed, our fitment team can help confirm before you purchase. Order now and we'll ship today — most orders arrive within 1–3 business days.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA03000GAABA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA03000GAABA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA03000GAABA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.