OEM Carrier High & Low Pressure Switch for Model CH13NA02500GABAA

These OEM pressure switches — 312926-252 (High Pressure Switch) and 312926-258 (Low Pressure Switch) — are the factory-specified replacements for the Carrier CH13NA02500GABAA condensing unit. Pressure switches prove that the inducer motor has established adequate draft before allowing the ignition sequence to proceed. A failed pressure switch causes the system to lock out before ignition, often displaying a fault code and leaving you with no heat. Common symptoms include the inducer running continuously with no ignition attempt, or repeated short-cycle lockouts.

  • Specs: 312926-252 — High Pressure Switch | 312926-258 — Low Pressure Switch | Factory-calibrated W.C. (water column) set points | Direct OEM replacement — no field adjustment required
  • OEM vs Generic: OEM pressure switches are factory-calibrated to the exact W.C. rating required for safe draft proving on the CH13NA02500GABAA. Aftermarket switches frequently carry loose tolerances that can cause nuisance lockouts or — more dangerously — allow operation under unsafe draft conditions.
  • Install difficulty: 3/5 — Turn off power at the disconnect and gas supply before beginning. Tools needed: 1/4" nut driver, flat-head screwdriver, needle-nose pliers, and a manometer if verifying W.C. readings. Always inspect the inducer hose for cracks or blockages before replacing the switch, as a collapsed hose is a common root cause of pressure switch failure.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: These switches are direct OEM replacements for Carrier CH13NA02500GABAA condensing units. Confirm which switch requires replacement — high (312926-252) or low (312926-258) — by referencing your control board fault code or testing continuity across each switch during an inducer cycle. If you need help confirming fitment, our HVAC parts specialists are standing by before you order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier CH13NA02500GABAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier CH13NA02500GABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier CH13NA02500GABAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.