Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 40A Contactor 2-Pole 24V Coil for CA16NA04900GBAAA
Carrier

OEM Carrier 40A Contactor 2-Pole 24V Coil for CA16NA04900GBAAA

SKU: CARRIE-CA16NA04900GBAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit CA16NA04900GBAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model CA16NA04900GBAAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Carrier CA16NA04900GBAAA split-system air conditioner. The contactor is the high-voltage relay that receives a 24V signal from your thermostat and closes the circuit to send line voltage to the compressor and condenser fan motor. When the contactor fails — due to worn or pitted contacts, a stuck plunger, or a burned coil — your outdoor unit will fail to start entirely, hum without running, or run continuously without shutting off.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40A contact rating | Direct OEM replacement for part number HN51KC024 | Factory-matched electrical tolerances
  • OEM vs Generic: OEM contactors use silver-alloy contact tips rated for thousands of switching cycles. Generic aftermarket units often use lower-grade contacts that pit and weld shut faster, leading to compressor burnout or a system that won't shut off — a costly repeat repair.
  • Install difficulty: 2/5 — Always disconnect power at both the disconnect box and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Line voltage terminals remain energized until the disconnect is fully open.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our climate-controlled warehouse.

Compatibility: Designed and factory-specified for the Carrier CA16NA04900GBAAA 4-ton, 16 SEER split-system condenser. Verify coil voltage and pole configuration on your unit's data plate before ordering. If you're unsure of fitment, our HVAC parts specialists are available to confirm compatibility before you purchase. Order today and receive fast, reliable shipping directly to your door.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier CA16NA04900GBAAA?
Yes. This is the factory-specified OEM contactor for the Carrier CA16NA04900GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier CA16NA04900GBAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.