Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole 30A 24V Coil Definite Purpose Contactor for C50A306061 — Ships Today
Carrier

OEM Carrier 2-Pole 30A 24V Coil Definite Purpose Contactor for C50A306061 — Ships Today

SKU: CARRIE-C50A306061-CONTACTOR-HN53CB115 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil 30A for Model C50A306061

This OEM replacement contactor is the factory-specified high-voltage relay for the Carrier C50A306061 commercial packaged unit. The contactor acts as the main power switch between your thermostat's 24V control signal and the high-voltage compressor and condenser fan circuits. When the contactor fails, the most common symptom is an air conditioner that simply won't turn on — the thermostat calls for cooling, the indoor blower runs, but the outdoor unit sits completely silent. Worn or pitted contacts can also cause intermittent operation, chattering, or the unit running continuously without shutting off.

  • Specs: 2-pole | 30A rated | 24V coil voltage | Heavy-duty silver-alloy contacts | Replaces OEM part numbers HN53CB115, HN53HF122, and HN53HG120
  • OEM vs Generic: This OEM contactor is built to Carrier's exact coil pull-in voltage and contact gap specifications. Generic contactors frequently use inferior contact materials that arc and pit prematurely, leading to repeat failures within one to two seasons.
  • Install difficulty: 2/5 — Disconnect power at the disconnect box and confirm zero voltage with a multimeter before proceeding. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring before removing the old contactor — wire placement is critical for safe reinstallation.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Orders placed before our daily cutoff ship the same business day from our warehouse.

Compatibility: Designed for the Carrier C50A306061 commercial packaged unit. Cross-references OEM part numbers HN53CB115, HN53HF122, and HN53HG120. Always verify coil voltage (24V) and amperage rating on your unit's data plate before ordering. Not sure about fitment? Our HVAC parts specialists confirm compatibility before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier C50A306061 — Ships Today?
Yes. This is the factory-specified OEM contactor for the Carrier C50A306061 — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier C50A306061 — Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online