OEM Carrier Contactor 2-Pole 24V Coil for C48A403561 — Ships Today
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for C48A403561 — Ships Today

SKU: CARRIE-C48A403561-CONTACTOR-HN53CB115 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model C48A403561

This OEM contactor (part number HN53CB115) is the factory-specified replacement for the Carrier C48A403561 packaged unit. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes the circuit to power the compressor and condenser fan motor. When it fails, the unit may not respond to cooling calls at all, run continuously without shutting off, or show visible pitting and burning on the contact points.

  • Specs: 2-pole configuration | 24V coil voltage | Factory-matched contact rating | OEM part number HN53CB115 | Direct drop-in replacement
  • OEM vs Generic: This OEM contactor is manufactured to Carrier's exact coil pull-in voltage and contact ampacity specifications. Generic contactors often use lower-grade silver-alloy contacts that pit prematurely under the high-amperage loads of packaged unit compressors, leading to premature failure and potential compressor damage.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before beginning work. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor to ensure correct reinstallation.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. In-stock and ships same business day from our warehouse.

Compatibility: Designed as a direct OEM replacement for the Carrier C48A403561 packaged unit. Verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — reach out before you buy for complete peace of mind. Order today and your part ships same business day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier C48A403561 — Ships Today?
Yes. This is the factory-specified OEM contactor for the Carrier C48A403561 — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier C48A403561 — Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.