Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 40A Contactor 2-Pole 24V Coil for C4850C50AK02561 | National HVAC Parts
Carrier

OEM Carrier 40A Contactor 2-Pole 24V Coil for C4850C50AK02561 | National HVAC Parts

SKU: CARRIE-C4850C50AK02561-CONTACTOR-HN53CB115 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor 2-Pole 24V Coil for Model C4850C50AK02561

This is the factory-specified OEM replacement contactor (part number HN53CB115) for the Carrier C4850C50AK02561 packaged unit. The contactor is the high-voltage relay that receives a 24V signal from the thermostat and closes the circuit to deliver line voltage to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a burned coil, or a stuck plunger — the system will either fail to start entirely, run continuously without shutting off, or trip the breaker repeatedly.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40A contact rating | Direct OEM replacement per part number HN53CB115 | Factory-matched contact material for longevity
  • OEM vs Generic: OEM contactors use precision-machined silver-alloy contacts that resist pitting and arcing far longer than generic alternatives. A failed generic contactor can damage the compressor — the most expensive component in your system.
  • Install Difficulty: 3/5 — Always disconnect power at the breaker and verify zero voltage with a multimeter before touching any wiring. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Line-voltage terminals carry lethal current — exercise extreme caution.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship the same business day from our climate-controlled warehouse.

Compatibility: Engineered as a direct OEM drop-in replacement for the Carrier C4850C50AK02561 packaged unit. Always verify your unit's data plate and existing contactor specifications — poles, coil voltage, and amperage — before ordering. Our technical team is available to confirm fitment. Order now and get your system back online fast — in stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier C4850C50AK02561 | National HVAC Parts?
Yes. This is the factory-specified OEM contactor for the Carrier C4850C50AK02561 | National HVAC Parts. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier C4850C50AK02561 | National HVAC Parts?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online