Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V for C4850C48AY03551
Carrier

OEM Carrier Contactor 2-Pole 24V for C4850C48AY03551

SKU: CARRIE-C4850C48AY03551-CONTACTOR-HN53CB115 Brand: Carrier
Guaranteed to fit C4850C48AY03551 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model C4850C48AY03551

This OEM replacement contactor is the factory-specified high-voltage relay for the Carrier C4850C48AY03551 packaged unit. The contactor serves as the primary switching device that allows the 24V thermostat signal to energize the compressor and condenser fan motor at line voltage. When the contactor fails — due to pitted or burned contacts, a welded contact, or a failed coil — the system will either refuse to start entirely, run continuously without shutting off, or trip the breaker repeatedly. Replaces OEM part numbers HN53CB115, HN53HF122, and HN53HG120.

  • Specs: 2-Pole configuration | 24V AC coil voltage | Factory-rated amperage for Carrier C4850C48AY03551 | Silver-alloy contact surfaces for long service life
  • OEM vs Generic: This OEM contactor meets Carrier's exact coil pull-in voltage and contact gap specifications. Aftermarket contactors frequently use lower-grade contact alloys that pit and arc prematurely, leading to callbacks and compressor damage.
  • Install difficulty: 2/5 — Shut off power at both the disconnect and breaker panel before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor to ensure correct reinstallation.
  • Warranty: 1-year OEM factory warranty. In-stock units ship same business day when ordered before cutoff.

Compatibility: Designed for the Carrier C4850C48AY03551 packaged unit. Cross-references OEM part numbers HN53CB115, HN53HF122, and HN53HG120 — verify your existing part number against this list before ordering. Not sure if this is the right fit? Our HVAC parts specialists confirm fitment before every order. Order now and get same-day shipping from our stocked warehouse.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier C4850C48AY03551?
Yes. This is the factory-specified OEM contactor for the Carrier C4850C48AY03551. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier C4850C48AY03551?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online