OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE164900
Carrier

OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE164900

SKU: CARRIE-09DE164900-CONTACTOR-HN52KC053 Brand: Carrier
Guaranteed to fit 09DE164900 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 35A 208/240V for Model 09DE164900

This OEM contactor (part number HN52KC053) is the factory-specified high-voltage relay replacement for the Carrier 09DE164900. The contactor acts as the main power switch between your thermostat's 24V control signal and the 208/240V supply feeding the compressor and condenser fan. When the contactor fails, the most common symptom is an air conditioner that simply will not turn on — the thermostat calls for cooling, the furnace or air handler responds, but the outdoor unit stays completely silent. A burned or pitted contactor can also cause intermittent operation, loud buzzing from the electrical panel area, or premature compressor failure due to voltage drop across worn contacts.

  • Specs: 2-pole | 35 Amp | 208/240V coil | Factory-matched OEM replacement | Part number HN52KC053
  • OEM vs Generic: This is a genuine Carrier OEM contactor, built to exact factory contact-gap and coil-pull-in specifications. Generic contactors often use thinner contact material, leading to faster pitting, arcing, and repeat failures — especially under the high inrush loads of a scroll compressor.
  • Install difficulty: 3/5 — Always shut off power at both the disconnect box and the breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, a multimeter to verify de-energized contacts, and electrical tape. Photograph all wiring before disconnecting terminals. The contactor mounts in the condenser's electrical compartment and typically takes 20–30 minutes to replace.
  • Warranty: 1-year OEM factory warranty. In-stock and ships the same business day from our warehouse.

Compatibility: Designed as the direct OEM replacement for Carrier model 09DE164900. Verify amperage, pole count, and coil voltage against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — call or chat now. Order by 3 PM and your part ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE164900?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE164900. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE164900?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.