Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE109230
Carrier

OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE109230

SKU: CARRIE-09DE109230-CONTACTOR-HN52KC053 Brand: Carrier
Guaranteed to fit 09DE109230 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 35A 208/240V — Model 09DE109230

The Carrier HN52KC053 is the factory-specified 2-pole contactor for the 09DE109230 unit. The contactor acts as a high-voltage relay, switching 208/240V power to the compressor and condenser fan motor whenever the thermostat calls for cooling. When this component fails, the control board sends the 24V signal but nothing happens — the outdoor unit stays completely silent even though the indoor air handler is running. A failed or pitted contactor is one of the most common causes of a no-cool call in residential and light-commercial HVAC systems.

  • Specs: 2-Pole | 35 Amps | 208/240V load voltage | 24V coil voltage | replaces OEM part number HN52KC053
  • OEM vs Generic: This OEM-grade contactor matches the exact coil pull-in voltage and contact ratings specified by Carrier for the 09DE109230, ensuring reliable switching under full-load conditions. Generic substitutes often use lower-grade contact materials that pit and arc prematurely, leading to repeat failures within a single season.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring before removal. Swap wires one-at-a-time to avoid miswiring.
  • Warranty & Shipping: 1-year OEM warranty coverage. Ships same business day from our warehouse when ordered before cutoff — get your system cooling again fast.

Compatibility: Designed for Carrier model 09DE109230. Always verify the part number on your existing contactor's label and confirm load amperage and coil voltage match before installation. Have questions about fit? Our HVAC parts specialists confirm compatibility before you order — no guesswork.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE109230?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE109230. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE109230?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online