Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE098C600
Carrier

OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE098C600

SKU: CARRIE-09DE098C600-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit 09DE098C600 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole 30A 120V Contactor HN52KC052 for Model 09DE098C600

This OEM contactor is the factory-specified replacement part for the Carrier 09DE098C600 HVAC system. The contactor is a high-voltage relay that engages and disengages power to the compressor and condenser fan motor every time a cooling or heating cycle begins or ends. When the contactor fails, the system will often fail to start entirely, run continuously without cycling off, or produce an audible buzzing or chattering from the electrical cabinet. Burned or pitted contacts are the most common cause of failure and can be visually confirmed on inspection.

  • Specs: 2-pole | 30 Amp | 120V coil | 50/60 Hz rated | OEM Part Number HN52KC052 — factory-matched for Carrier 09DE098C600
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part (FAP), built to exact OEM tolerances and materials. Generic contactors frequently use lower-grade contact alloys that pit and fail faster under cycling loads, reducing compressor protection and system lifespan.
  • Install difficulty: 3/5 — Always disconnect and lock out power at the disconnect box before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a multimeter to verify coil voltage. Photograph all wire connections before removal. Terminals are typically screw-type for straightforward swap.
  • Warranty: 1-year OEM factory warranty. In stock and ships the same business day from our warehouse.

Compatibility: Designed for the Carrier model 09DE098C600. Verify your unit's data plate matches the 120V coil voltage and 2-pole, 30A specification before ordering. If you have any fitment questions, our HVAC parts specialists can confirm compatibility before you buy — contact us today and get your system back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE098C600?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE098C600. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE098C600?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.