Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE098C230
Carrier

OEM Carrier 2-Pole Contactor 35A 208/240V for 09DE098C230

SKU: CARRIE-09DE098C230-CONTACTOR-HN52KC053 Brand: Carrier
Guaranteed to fit 09DE098C230 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 35A 208/240V for Model 09DE098C230

This is the factory OEM replacement contactor for Carrier model 09DE098C230, sourced directly from Carrier (part number HN52KC053). The contactor is the primary high-voltage switching relay in your condensing unit — when the thermostat calls for cooling, the 24V control circuit energizes the contactor coil, closing the high-voltage contacts that power the compressor and condenser fan motor. A failed contactor is one of the most common reasons an air conditioner simply will not turn on, hums continuously without starting, or trips the breaker on startup. Replacing it with the correct OEM part ensures proper contact gap, coil pull-in voltage, and amperage rating — all critical to compressor longevity.

  • Specs: 2-pole | 35 Amps | 208/240V load voltage | 24V coil | Factory OEM part number HN52KC053
  • OEM vs Generic: OEM contactors use silver-alloy contacts rated to factory arc-interruption standards. Generic contactors often use lower-grade alloys that pit and weld faster under the high-inrush current of compressor startups, leading to premature failure.
  • Install difficulty: 2/5 — Turn off power at the disconnect and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before disconnecting. Verify coil voltage matches your control board output (24V).
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for use in Carrier model 09DE098C230. Always verify the part number on your existing contactor's label before ordering. Our fitment team is available to confirm compatibility prior to purchase — just reach out before you order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE098C230?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE098C230. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE098C230?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.