OEM Carrier Definite Purpose Contactor for 09DE064C800 HVAC Unit
Carrier

OEM Carrier Definite Purpose Contactor for 09DE064C800 HVAC Unit

SKU: CARRIE-09DE064C800-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor for 09DE064C800 HVAC Unit

The contactor in your Carrier 09DE064C800 is the electrically-operated switch that closes to send line voltage to the compressor and condenser fan whenever the thermostat calls for cooling. As its contacts pit and burn from years of arcing, you'll notice the outdoor unit failing to start, a loud chatter or buzz at the contactor, the unit running when it shouldn't (welded contacts stuck closed), or cooling that comes and goes. Insects and debris lodged under the contacts are a frequent culprit. This genuine OEM definite-purpose contactor matches the pole configuration (1 or 2 pole), the contact amperage rating (e.g., 30–40 FLA), and the 24V coil voltage Carrier specified for the 09DE064C800. Its silver-alloy contacts and properly sized coil are built for the switching load of this equipment. Why OEM matters here: generic contactors often use undersized, lower-grade contacts that pit and weld faster, plus weaker coils that chatter under normal control voltage. A welded contactor can run the compressor continuously and destroy it — making the correct contact rating critical to compressor survival. Install difficulty: 2/5. Tools needed: a 1/4" nut driver, a screwdriver, and a multimeter. #1 safety warning: pull the disconnect before touching the contactor — the line-side terminals stay live and lethal even when the thermostat is off. Photograph the wiring and transfer leads one terminal at a time to avoid errors. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model 09DE064C800. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE064C800 HVAC Unit?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE064C800 HVAC Unit. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE064C800 HVAC Unit?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.