Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE064510
Carrier

OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE064510

SKU: CARRIE-09DE064510-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit 09DE064510 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 120V Coil — Model 09DE064510 (HN52KC052)

This is the genuine OEM Carrier contactor (part #HN52KC052) factory-specified for the Carrier 09DE064510. The contactor is a high-voltage switching relay that controls electrical flow to the compressor and condenser fan motor. When the thermostat calls for cooling, the 120V coil energizes, closing the contacts and allowing line voltage to reach the load components. When it fails, you'll typically experience symptoms like the system failing to start, audible chattering or humming at the unit, or — in a welded-contact failure — the system running continuously even when the thermostat is satisfied.

  • Specs: 2-Pole | 30 Amp (FLA) | 120V Coil | 50/60 Hz | Factory OEM tolerance — drop-in replacement for HN52KC052
  • OEM vs Generic: OEM contactors use factory-matched silver-alloy contact tips rated to exact amperage thresholds. Generic contactors often use lower-grade contacts that pit and weld sooner, risking compressor lockout or continuous-run damage to the refrigerant circuit.
  • Install Difficulty: 2/5 — Turn off power at both the breaker and disconnect before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a non-contact voltage tester. Always photograph all wiring terminals before disconnecting. Reconnect line-voltage leads (L1/L2) to top terminals and load leads (T1/T2) to bottom.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before cut-off.

Compatibility: Engineered as the direct OEM replacement for Carrier model 09DE064510. Verify coil voltage (120V) and amperage (30A) against your unit's data plate before ordering — do not substitute a 24V coil version for this application. Have questions about fitment? Our HVAC parts team verifies compatibility before you buy. Order today and ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE064510?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE064510. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE064510?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.