Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044C600
Carrier

OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044C600

SKU: CARRIE-09DE044C600-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit 09DE044C600 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole 30 Amp 120V Contactor HN52KC052 for Model 09DE044C600

This is the genuine OEM factory-specified replacement contactor for the Carrier 09DE044C600. The contactor is the high-voltage switching relay that connects and disconnects power to the compressor and condenser fan motor every time the thermostat calls for cooling. When this part fails, you may notice the system chattering, humming without starting, running continuously without shutting off, or refusing to turn on at all — all classic signs of a worn or burned contactor that needs immediate replacement.

  • Specs: 2-Pole | 30 Amp FLA | 120V Coil | 50/60 Hz | Factory OEM part number HN52KC052 (cross-reference: 3100-20T628)
  • OEM vs Generic: This genuine Carrier OEM contactor meets exact factory contact gap, coil pull-in voltage, and arc suppression specs. Aftermarket contactors often use lower-grade contact materials that pit and weld prematurely under high-cycle HVAC loads, shortening system life.
  • Install difficulty: 2/5 — Always disconnect power at the breaker and discharge any residual voltage before servicing. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, a multimeter. Photograph all wiring connections before removal. One-for-one terminal swap makes this a straightforward field replacement.
  • Warranty: Backed by a 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed as the direct OEM replacement for Carrier model 09DE044C600. Also cross-references to Bryant and Payne equipment sharing the HN52KC052 specification. Always verify coil voltage (120V) and amperage rating on your unit's data plate before ordering. Have a fitment question? Our HVAC parts specialists verify compatibility before you buy — contact us today and we'll get your system back up fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE044C600?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE044C600. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE044C600?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.