Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044900
Carrier

OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044900

SKU: CARRIE-09DE044900-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit 09DE044900 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 120V Coil — HN52KC052 for Model 09DE044900

This OEM Carrier contactor (part #HN52KC052) is the factory-specified high-voltage relay for the Carrier 09DE044900 HVAC unit. The contactor acts as the primary electrical switch that energizes the compressor and condenser fan motor every time your thermostat calls for cooling or heating. When the 24V control signal arrives, the contactor's 120V coil pulls in the armature, closing the high-voltage circuit to your load. When a contactor fails, symptoms include an air conditioner that won't turn on at all, a system that hums without starting, welded contacts that keep the compressor running constantly, or visible pitting and burn marks on the contact surfaces.

  • Specs: 2-Pole | 30 Amp | 120V AC Coil | 50/60 Hz | OEM Part #HN52KC052 | Factory-matched electrical ratings
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part. OEM contactors use silver-alloy contacts rated for your unit's exact amperage draw, preventing the premature pitting and arcing common in generic aftermarket units that use lower-grade contact materials.
  • Install difficulty: 3/5 — Always disconnect power at the breaker and verify zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, camera or phone to photograph existing wiring before disconnection. Tag each wire before removal.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Engineered as a direct OEM replacement for Carrier model 09DE044900. Verify pole count, amperage, and coil voltage against your unit's data plate and existing contactor label before ordering. Our parts specialists are available to confirm fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE044900?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE044900. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE044900?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online