Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044800
Carrier

OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE044800

SKU: CARRIE-09DE044800-CONTACTOR-HN52KC052 Brand: Carrier
Guaranteed to fit 09DE044800 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole 30 Amp 120V Contactor HN52KC052 for Model 09DE044800

This genuine OEM Carrier contactor (part# HN52KC052) is the factory-specified replacement for the Carrier 09DE044800 unit. The contactor acts as the high-voltage switching relay that connects and disconnects power to critical components — including the compressor and condenser fan motor — every time your system cycles. When the contactor begins to fail, you'll notice symptoms such as audible chattering or humming at the unit, the system refusing to start, or conversely, the AC running continuously and failing to shut off. In severe cases, burned or pitted contacts cause total system lockout.

  • Specs: 2-Pole | 30 Amp (FLA) | 120V Coil | 50/60Hz | Definite Purpose Contactor | Factory-matched contact gap and spring tension
  • OEM vs Generic: This is a genuine Carrier OEM part — not a universal substitute. OEM contactors meet exact coil pull-in voltage specs and contact material standards. Generic contactors can exhibit premature pitting, coil dropout under load, and shortened service life, risking compressor damage.
  • Install Difficulty: 3/5 — High-voltage work requires disconnecting power at the disconnect box AND verifying zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph all wiring connections before removal.
  • Warranty: 1-year OEM factory warranty. In-stock units ship same business day from our warehouse so your system is back up fast.

Compatibility: Designed for the Carrier model 09DE044800. Verify your existing contactor's pole count, amperage rating, and coil voltage against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you purchase — call or chat today. Order now and get same-day shipping on in-stock inventory.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier 09DE044800?
Yes. This is the factory-specified OEM contactor for the Carrier 09DE044800. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier 09DE044800?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.