Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Single-Pole Contactor for TCA224AKC4 — 25A 24V Coil | Ships Today
Tempstar

Tempstar Single-Pole Contactor for TCA224AKC4 — 25A 24V Coil | Ships Today

SKU: 1050699-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole contactor (part number 1050699) for the Tempstar TCA224AKC4 air conditioning condenser. The contactor is the heavy-duty switch that delivers line voltage to the compressor and condenser fan motor on a call for cooling. Its 24-volt coil is energized by the low-voltage control circuit; the resulting magnetic field snaps the contacts closed and powers the high-current loads. Rated at 25 amps with a 24V coil, this contactor is sized for the inrush and running demands of a residential condensing unit. Contactors are a frequent failure point because their contacts arc every time they open and close — over thousands of cycles they pit, corrode, and can weld shut or fail to close at all, leaving the outdoor unit dead or stuck running.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, Single Pole (1P)
Brand Tempstar
Contact Rating 25 Amps
Coil Voltage 24V
Poles 1
Application AC Condensing Unit

Compatibility

This contactor is the factory-specified replacement for the Tempstar TCA224AKC4 condensing unit. The same 1050699 contactor is also used across many ICP-family condensers, including matching Heil, Comfortmaker, and Carrier-built models sharing the TCA224 platform. Always confirm the part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service panel to expose the electrical compartment.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor, reconnect each wire exactly per your photo, and confirm the coil terminals receive the 24V control leads.
  6. Test — Restore power, call for cooling, and verify the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums but the compressor and fan do not start.
  • Visible pitting, burning, or welded contacts.
  • Buzzing or chattering coil noise.
  • Intermittent cooling or a unit that short-cycles.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA224AKC4 — 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA224AKC4 — 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA224AKC4 — 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online