Overview

This OEM oval run capacitor (part #1170643) is the blower motor run capacitor for the Tempstar T9MPD050F12C2 modulating gas furnace. Rated at 5 MFD and 370 volts, it delivers the phase-shifted current that lets the blower motor start under load and run efficiently throughout the heating and cooling seasons. A run capacitor charges and discharges on every cycle; as it degrades it loses capacitance, causing the motor to draw high amperage, overheat, and eventually fail to start. Watch for a blower that hums without spinning, weak airflow, intermittent no-heat or no-cool calls, or a furnace tripping on its high-limit because air movement has dropped. Swapping the capacitor is a fast, inexpensive repair that restores full blower performance.

Specifications

Spec Value
OEM Part Number 1170643
Type Single Run Capacitor, Oval
Brand Tempstar (ICP / Heil)
Capacitance 5 MFD
Voltage Rating 370 VAC
Mounting Oval, strap mount
Fit OEM Replacement

Compatibility

Direct-fit replacement for the Tempstar T9MPD050F12C2 and other ICP, Heil, Comfortmaker, and Tempstar furnaces using an oval 5 MFD 370V blower capacitor. Always confirm the MFD and voltage stamped on your existing capacitor before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Discharge the capacitor across its terminals with an insulated resistor before touching.
  2. Access — Remove the furnace blower compartment service panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Loosen the oval mounting strap, slide the old capacitor out, and label the leads.
  5. Install — Seat the new capacitor in the strap, reconnect each lead per your photo, and tighten the bracket.
  6. Test — Restore power and confirm the blower starts smoothly and ramps to full speed.

Signs You Need a Replacement

  • Blower motor hums but will not start spinning
  • Bulged, leaking, or swollen capacitor casing
  • Weak or inconsistent airflow from registers
  • Furnace tripping on high-limit from low air movement

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Tempstar T9MPD050F12C2 — 5 MFD 370V Oval | Ships Today?
Yes. This is the factory-specified OEM capacitor for the Tempstar T9MPD050F12C2 — 5 MFD 370V Oval | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Tempstar T9MPD050F12C2 — 5 MFD 370V Oval | Ships Today?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.