Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar PTAC Thermostat Kit for TEB07K00STA — Knob + Wall Thermostat | Ships Today
Tempstar

Tempstar PTAC Thermostat Kit for TEB07K00STA — Knob + Wall Thermostat | Ships Today

SKU: 1058437-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM PTAC thermostat assembly for the Tempstar TEB07K00STA packaged terminal unit, covering the wall thermostat (OEM 1058517) and its control knob (OEM 1058437). The thermostat reads room temperature and switches the 24V control circuit to the unit's relays and compressor, telling the PTAC when to heat or cool. A failed thermostat shows up as no response to setpoint changes, a unit that won't cycle on, continuous running, or a cracked/missing knob that won't turn. Installing the correct OEM part restores accurate temperature control and proper cycling.

Specifications

Spec Value
Part Number (Thermostat) 1058517
Part Number (Knob) 1058437
Type PTAC Wall Thermostat + Knob
Brand Tempstar (Heil / ICP)
Control Voltage 24V
Fits Model TEB07K00STA

Compatibility

Designed for the Tempstar TEB07K00STA PTAC and other TEB07-series packaged terminal units sharing the same ICP/Heil/Tempstar control platform. Always confirm your unit's model and part number against the OEM numbers above before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the front grille and control-panel cover to reach the thermostat.
  3. Document — Photograph all thermostat wire terminals before disconnecting.
  4. Remove — Pull the old knob, disconnect the low-voltage leads, and unscrew the thermostat from its bracket.
  5. Install — Mount the new thermostat, reconnect leads per your photo, and press on the new knob.
  6. Test — Restore power and verify the unit responds to setpoint changes in heat and cool.

Signs You Need a Replacement

  • Unit ignores setpoint changes or won't turn on
  • Continuous running with no cycling
  • Control knob is cracked, missing, or spins freely
  • Erratic or inaccurate room temperature control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Thermostat fit my Tempstar TEB07K00STA — Knob + Wall Thermostat | Ships Today?
Yes. This is the factory-specified OEM thermostat for the Tempstar TEB07K00STA — Knob + Wall Thermostat | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the thermostat on my Tempstar TEB07K00STA — Knob + Wall Thermostat | Ships Today?
Refer to your equipment service manual for model-specific steps. General approach: turn off power, photograph connections, remove old part, install new part, restore power and test. For gas components, hire a licensed technician. Email info@nationalhvacparts.com for guidance.
What symptoms mean I need a new thermostat?
Common symptoms: unusual noises, intermittent operation, complete failure, or visible damage. Visit our diagnostic hub for symptom-based troubleshooting.
Is this thermostat compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar thermostat?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online