Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar PTAC Thermostat for TEB12K25DCA — 24V with Low-Temp Protection | Ships Today
Tempstar

Tempstar PTAC Thermostat for TEB12K25DCA — 24V with Low-Temp Protection | Ships Today

SKU: 1058437-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM PTAC thermostat package for the Tempstar TEB12K25DCA unit, including the 24V thermostat body (OEM 1058517), the low-temperature protection thermostat (OEM 1059022), and the matching control knob (OEM 1058437). The primary thermostat switches the 24V control circuit for cooling, heating, and fan; the low-temp stat protects the system by preventing operation that could lead to coil freeze-up or compressor damage in cold conditions. When either control fails, the PTAC may run continuously, refuse to maintain setpoint, lock out unexpectedly, or stop responding to the dial. A cracked or stripped knob is also covered with the correct OEM replacement.

Specifications

Spec Value
OEM Part Numbers 1058517 (Thermostat), 1059022 (Low-Temp Stat), 1058437 (Knob)
Type PTAC Mechanical Thermostat + Low-Temp Protection
Brand Tempstar / ICP / Heil
Control Voltage 24V
Fits Model TEB12K25DCA
Includes Thermostat body + low-temp stat + knob

Compatibility

A direct-fit replacement for the Tempstar TEB12K25DCA PTAC. The ICP/Tempstar/Heil TEB12K25 family of packaged terminal units shares a common parts platform, so confirm your unit's model and serial tag before ordering. This is the integrated PTAC control set, not a programmable wall thermostat.

Installation Guide

  1. Safety First — Disconnect power at the unit cord/disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the PTAC front cover and control box panel.
  3. Document — Photograph all thermostat and low-temp stat wiring before disconnecting.
  4. Remove — Pull the old knob, release the mounting clips/screws, and disconnect both stats.
  5. Install — Mount the new thermostat and low-temp stat, reconnect each lead per your photo, and press on the new knob.
  6. Test — Restore power and confirm normal setpoint response plus correct low-temp lockout behavior.

Signs You Need a Replacement

  • Unit runs nonstop or will not maintain the set temperature
  • Nuisance low-temp lockouts or coil freeze-ups
  • No response when turning the temperature dial
  • Cracked, loose, or stripped control knob

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Thermostat fit my Tempstar TEB12K25DCA — 24V with Low-Temp Protection | Ships Today?
Yes. This is the factory-specified OEM thermostat for the Tempstar TEB12K25DCA — 24V with Low-Temp Protection | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the thermostat on my Tempstar TEB12K25DCA — 24V with Low-Temp Protection | Ships Today?
Refer to your equipment service manual for model-specific steps. General approach: turn off power, photograph connections, remove old part, install new part, restore power and test. For gas components, hire a licensed technician. Email info@nationalhvacparts.com for guidance.
What symptoms mean I need a new thermostat?
Common symptoms: unusual noises, intermittent operation, complete failure, or visible damage. Visit our diagnostic hub for symptom-based troubleshooting.
Is this thermostat compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar thermostat?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online