Overview

This OEM pressure switch set keeps your Tempstar TSH542HKA200 heat pump operating safely by monitoring refrigerant pressure on both the high and low sides. The high-pressure switch (part 1184656) opens to shut down the compressor when discharge pressure climbs too high — a common result of a dirty condenser coil, blocked airflow, or an overcharged system. The low-pressure switch (part 1184655) protects against loss of charge, a failed metering device, or low ambient operation. When either switch fails, the unit may short-cycle, fail to start, or lock out entirely. Replacing both switches as a set ensures complete refrigerant safety protection.

Specifications

Spec Value
OEM Part Numbers 1184656 (HI), 1184655 (LO)
Type High & Low Refrigerant Pressure Switch
Brand Tempstar (ICP / Heil)
Function Compressor protection
Fitment OEM direct replacement

Compatibility

Engineered for the Tempstar TSH542HKA200 heat pump. Because ICP, Heil, Tempstar, Comfortmaker, and Day & Night units share common components, these switches also fit many equivalent models built on the same platform. Always confirm against your unit's OEM part numbers.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter. Recover or confirm system is not under pressure where required.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all wiring before disconnecting.
  4. Remove — Disconnect the spade terminals from the failed switch and unthread/release it from the refrigerant port (Schrader-style depressor type, no charge loss).
  5. Install — Thread the new switch onto the matching port and reconnect wiring per your photo.
  6. Test — Restore power and verify the system starts and runs without nuisance lockout.

Signs You Need a Replacement

  • Compressor won't start or trips on lockout
  • System short-cycles on and off
  • Switch fails a continuity test at normal operating pressure
  • Visible corrosion or damaged terminals on the switch body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar TSH542HKA200 — Hi & Lo Refrigerant Switches | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar TSH542HKA200 — Hi & Lo Refrigerant Switches | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar TSH542HKA200 — Hi & Lo Refrigerant Switches | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online