Overview

This OEM refrigerant pressure switch set protects the compressor on your Tempstar TSH442GKA101 heat pump. It includes the high-pressure switch (Part No. 1184656) and the low-pressure switch (Part No. 1184655). These 24V safety switches monitor system refrigerant pressure and open the control circuit to shut the unit down before damage occurs — the high-pressure switch trips on a blocked condenser, overcharge, or failed fan, while the low-pressure switch trips on a refrigerant leak, undercharge, or restricted metering device. Typical failure symptoms include a unit that short-cycles, trips out on safety lockout, or refuses to start because a switch is stuck open. Replacing a faulty switch restores reliable protection and normal operation.

Specifications

Spec Value
High-Pressure Switch 1184656
Low-Pressure Switch 1184655
Type Auto-Reset Refrigerant Pressure Switch
Brand Tempstar (ICP / Heil)
Circuit Voltage 24V
Function Compressor High / Low Pressure Protection

Compatibility

Direct-fit replacement for the Tempstar TSH442GKA101 heat pump and related ICP / Heil / Comfortmaker units using part numbers 1184656 and 1184655. Verify the part numbers stamped on your existing switches before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the refrigerant lines and control wiring.
  3. Document — Photograph the wire routing on each switch before disconnecting.
  4. Remove — Disconnect the spade terminals and unscrew the switch from its Schrader-style fitting; expect minimal refrigerant loss on a sealed self-piercing port.
  5. Install — Thread the new switch onto the matching port and reconnect the control wires per your photo.
  6. Test — Restore power, confirm the switches stay closed under normal pressure and the unit runs.

Signs You Need a Replacement

  • Unit trips out on a high- or low-pressure safety lockout
  • Compressor short-cycles or won't start
  • Switch reads open on a multimeter at normal operating pressure
  • Corroded terminals or a cracked switch body

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar TSH442GKA101 — Hi & Lo 24V | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar TSH442GKA101 — Hi & Lo 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar TSH442GKA101 — Hi & Lo 24V | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.