Overview

This is a genuine OEM high-pressure and low-pressure switch set for the Tempstar TSH530HKA100 heat pump. These 24V refrigerant pressure switches protect the compressor by opening the control circuit when system pressure rises too high (high-pressure switch, OEM 1184656) or drops too low (low-pressure switch, OEM 1184655). When a switch fails, the unit may short-cycle, refuse to start, or lock out on a safety fault. Replacing both switches as a pair restores reliable compressor protection and prevents nuisance trips.

Specifications

Spec Value
Part Numbers 1184656 (HI), 1184655 (LO)
Type Refrigerant Pressure Switch (High & Low)
Brand Tempstar / Heil / ICP
Control Voltage 24V
Function Compressor Safety Lockout
Fit OEM Direct Replacement

Compatibility

Engineered for the Tempstar TSH530HKA100 heat pump and shared ICP/Heil/Comfortmaker platforms using the same chassis. Always confirm the part numbers stamped on your existing switches before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the refrigerant lines and control wiring.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Recover or isolate refrigerant as required, then unthread the Schrader-style or brazed switch and disconnect its leads.
  5. Install — Mount the new switch, torque the fitting, and reconnect the leads per your photo.
  6. Test — Restore power and verify the compressor runs and the safeties hold under normal pressures.

Signs You Need a Replacement

  • Compressor locks out or trips on a high- or low-pressure fault.
  • Unit short-cycles or will not start in heat or cool mode.
  • Switch contacts fail to close even at normal operating pressure.
  • Visible corrosion, refrigerant leak, or damaged terminals at the switch body.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar TSH530HKA100 — 24V Heat Pump | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar TSH530HKA100 — 24V Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar TSH530HKA100 — 24V Heat Pump | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.