Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Low-Temp PTAC Thermostat for THB07R34DCA — OEM Knob | Ships Today
Tempstar

Tempstar Low-Temp PTAC Thermostat for THB07R34DCA — OEM Knob | Ships Today

SKU: 1058437-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM thermostat package services the Tempstar THB07R34DCA packaged terminal air conditioner (PTAC) and includes the standard thermostat assembly (1058517), the low-temperature thermostat (1059022), and the matching control knob (1058437). The low-temp thermostat is the freeze-protection control that prevents the evaporator coil from icing over and keeps the conditioned space from dropping below a safe minimum — critical in cold-climate hotel rooms and unoccupied units. The standard thermostat handles occupant comfort by cycling the compressor and fan to the dial setpoint. Common failure symptoms include the unit failing to respond to the dial, the coil freezing during heating or cooling, short cycling, and a knob that spins freely. Replacing the OEM thermostat set restores both reliable comfort control and freeze protection.

Specifications

Spec Value
Part Numbers 1058517 (thermostat), 1059022 (low-temp), 1058437 (knob)
Type PTAC thermostat with low-temp protection
Brand Tempstar
Control Voltage 24V
Fit OEM direct replacement
Application Packaged terminal air conditioner

Compatibility

Designed as a direct-fit replacement for the Tempstar THB07R34DCA PTAC chassis. ICP, Heil, and Comfortmaker THB-series packaged terminal units built on the same platform share this control hardware and are serviced by the same thermostat, low-temp control, and knob. Match your part numbers against the originals before ordering.

Installation Guide

  1. Safety First — Disconnect power at the cord or breaker and verify zero voltage with a multimeter before handling wiring.
  2. Access — Remove the front grille and control-panel cover to reach the thermostat and low-temp control.
  3. Document — Photograph all wiring, including the low-temp sensor routing, before disconnecting.
  4. Remove — Pull the old knob, release the thermostat and low-temp control mounts, and detach the spade terminals.
  5. Install — Mount the new thermostat (1058517) and low-temp control (1059022), reconnect each wire per your photo, and press on the new knob (1058437).
  6. Test — Restore power and confirm the unit cycles correctly and the low-temp control protects against coil freeze-up.

Signs You Need a Replacement

  • Unit does not respond to the dial setting
  • Evaporator coil freezes or the room drops below the safe minimum temperature
  • Knob is loose, cracked, or gritty to turn
  • Compressor short cycles or runs continuously

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Thermostat fit my Tempstar THB07R34DCA — OEM Knob | Ships Today?
Yes. This is the factory-specified OEM thermostat for the Tempstar THB07R34DCA — OEM Knob | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the thermostat on my Tempstar THB07R34DCA — OEM Knob | Ships Today?
Refer to your equipment service manual for model-specific steps. General approach: turn off power, photograph connections, remove old part, install new part, restore power and test. For gas components, hire a licensed technician. Email info@nationalhvacparts.com for guidance.
What symptoms mean I need a new thermostat?
Common symptoms: unusual noises, intermittent operation, complete failure, or visible damage. Visit our diagnostic hub for symptom-based troubleshooting.
Is this thermostat compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar thermostat?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online