OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM low-pressure switch (part number 1184655) is the refrigerant-side safety control for the Tempstar TCH624GKA200. Wired in series with the 24V control circuit, it continuously monitors suction-line pressure and opens the circuit to shut the compressor down if pressure drops below a safe threshold — protecting against a loss of charge, a clogged metering device, or frozen evaporator conditions. A low-pressure switch that fails open will prevent the system from running, while one that sticks closed removes critical compressor protection. Installing a fresh OEM switch restores proper low-charge protection and reliable cooling/heat-pump operation.
| Spec | Value |
|---|---|
| Part Number | 1184655 |
| Type | Low Pressure Switch (Refrigerant Safety Cutout) |
| Brand | Tempstar (ICP / Heil) |
| Circuit Voltage | 24 VAC |
| Function | Opens 24V control circuit on low suction pressure |
Designed for the Tempstar TCH624GKA200 heat pump and used across ICP-family outdoor units (Heil, Comfortmaker, Tempstar) sharing the same refrigerant-circuit safety design. Verify the connection style and refrigerant type of your existing switch before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.