Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Low Pressure Switch for T4H524GKD200 — OEM 1177594 Refrigerant Safety Assembly | Ships Today
Tempstar

Tempstar Low Pressure Switch for T4H524GKD200 — OEM 1177594 Refrigerant Safety Assembly | Ships Today

SKU: 1177594-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine Tempstar low pressure switch assembly (OEM #1177594) is a refrigerant-side safety control on your T4H524GKD200. It continuously senses suction-line pressure and opens the 24V control circuit if pressure drops too low — a sign of loss of charge, a refrigerant leak, a blocked metering device, or extreme low ambient operation. By shutting down the compressor before it runs starved, the switch prevents overheating and costly compressor failure. A faulty switch can either nuisance-trip and lock out a healthy system or fail closed and remove protection entirely.

Specifications

Spec Value
Part Number 1177594
Type Low Pressure Switch Assembly
Function Loss-of-Charge / Low-Pressure Safety
Control Circuit 24V
Brand Tempstar (ICP / Heil)
Fit Genuine OEM

Compatibility

Designed for the Tempstar T4H524GKD200 and compatible across ICP-family outdoor units (Tempstar, Heil, Comfortmaker, Arcoaire) using this low-pressure safety assembly. Confirm the original part number and refrigerant type before installing.

Installation Guide

  1. Safety First — Disconnect power; verify zero voltage with a multimeter. Note that this part connects to the sealed refrigerant system.
  2. Access — Remove the outdoor unit service panel.
  3. Document — Photograph the switch wiring and mounting before disconnecting.
  4. Remove — Disconnect the 24V leads; if the switch is brazed/threaded into the line, recover refrigerant first per EPA guidelines (qualified technician).
  5. Install — Fit the new switch, evacuate and recharge the system as required, and reconnect the control leads per your photo.
  6. Test — Restore power, run the system, and confirm pressures are normal and the switch is closed during operation.

Signs You Need a Replacement

  • Compressor locks out on a low-pressure fault with adequate charge
  • Nuisance trips or intermittent no-cool
  • Switch fails to open during an actual low-charge condition
  • Corroded terminals or a damaged sensing port

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar T4H524GKD200 — OEM 1177594 Refrigerant Safety Assembly | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar T4H524GKD200 — OEM 1177594 Refrigerant Safety Assembly | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar T4H524GKD200 — OEM 1177594 Refrigerant Safety Assembly | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online