The Tempstar low pressure switch assembly (OEM #1177594) is a refrigerant-side safety control on your T4H461GKD100 heat pump. It senses suction-line pressure and opens the control circuit to shut down the compressor whenever pressure drops below a safe threshold — protecting the compressor from running on a low charge, a restricted line, or a winter loss-of-charge condition. When this switch fails or sticks, the result is either nuisance lockouts (system won't run even when charge is fine) or, worse, a compressor allowed to run dry. This genuine OEM assembly is pre-calibrated to the correct cut-out and cut-in pressures for your unit.

Specifications

Spec Value
Part Number 1177594
Type Low Pressure Switch Assembly
Brand Tempstar (ICP / Heil)
Function Loss-of-charge / low-pressure cutout
Application Heat Pump Refrigerant Circuit
Fits Model T4H461GKD100

Compatibility

Built for the Tempstar T4H461GKD100 heat pump and other ICP-family condensers (Heil, Comfortmaker, Arcoaire) sharing the same refrigerant safety circuit. Confirm OEM number 1177594 and the fitting/connection type against your original switch before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's control/service panel.
  3. Document — Photograph the switch wiring and its plumbing connection point.
  4. Remove — Disconnect the electrical leads, then unthread or unclip the switch from its Schrader/port fitting (most assemblies seal on a valve core, so refrigerant recovery is usually not required — confirm for your fitting type).
  5. Install — Thread on the new switch with the supplied gasket/seal, reconnect the leads per your photo, and check for leaks.
  6. Test — Restore power and verify the system runs and that the switch is not holding the circuit open.

Signs You Need a Replacement

  • Compressor won't start and control board reports low-pressure lockout
  • Nuisance trips with a verified-good refrigerant charge
  • Switch fails to open on an actual low-charge condition
  • Corroded terminals or a cracked/leaking switch body

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar T4H461GKD100 — OEM 1177594 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar T4H461GKD100 — OEM 1177594 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar T4H461GKD100 — OEM 1177594 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online