Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Low Pressure Switch Assembly for T4H430GKD100 — OEM 1177594 | Ships Today
Tempstar

Tempstar Low Pressure Switch Assembly for T4H430GKD100 — OEM 1177594 | Ships Today

SKU: 1177594-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM low pressure switch assembly (part number 1177594) for the Tempstar T4H430GKD100 outdoor unit. The low pressure switch is a safety control that monitors suction-side refrigerant pressure and opens the control circuit if pressure drops too low — protecting the compressor from running on a low charge, a restriction, or a frozen coil. When the switch fails or sticks open, the unit may short-cycle, lock out, or refuse to start even with a proper charge; when it sticks closed, it can let the compressor run unprotected. This factory assembly is matched to the original cut-out and cut-in pressure settings for reliable compressor protection.

Specifications

Spec Value
Part Number 1177594
Type Low Pressure Switch Assembly
Brand Tempstar
Function Suction-side low-pressure compressor protection
Application Outdoor condensing/heat-pump unit
Fits Model T4H430GKD100

Compatibility

Direct OEM replacement for the Tempstar T4H430GKD100 outdoor unit and other ICP-family units (Heil, Comfortmaker, ICP) using the same low pressure switch assembly. Confirm the original part number and fitting/connection type before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter; recover or isolate refrigerant if the switch is not on a Schrader fitting.
  2. Access — Remove the service/electrical panel to reach the switch and its leads.
  3. Document — Photograph the wiring and refrigerant connection before disconnecting.
  4. Remove — Disconnect the two control wires, then unthread the switch from its Schrader port or fitting.
  5. Install — Thread on the new switch (use a new core/seal as needed), reconnect the control wires per your photo.
  6. Test — Restore power, check for leaks, and confirm the unit starts and stays running under normal pressures.

Signs You Need a Replacement

  • Unit locks out or won't start despite a correct refrigerant charge.
  • Compressor short-cycles on the low-pressure safety.
  • Switch tests open at normal operating pressure (or won't open when it should).
  • Corroded, leaking, or physically damaged switch body or fitting.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar T4H430GKD100 — OEM 1177594 | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar T4H430GKD100 — OEM 1177594 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar T4H430GKD100 — OEM 1177594 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online