Overview

This OEM low pressure switch assembly (Tempstar part 1177594) protects the compressor on the T4H336GKD100 by opening the control circuit when refrigerant suction pressure drops below a safe threshold — typically from a refrigerant leak, restricted metering device, or frozen coil. A failed or stuck switch can lock out the system, cause short-cycling, or allow the compressor to run dry. This is a direct OEM replacement with the factory pressure setpoint and connection fittings.

Specifications

Spec Value
Part Number 1177594
Type Low Pressure Switch Assembly
Brand Tempstar
Control Voltage 24V
Function Compressor Loss-of-Charge Protection
Fitment OEM Direct Replacement

Compatibility

Designed for the Tempstar T4H336GKD100 and shared ICP / Heil / Comfortmaker condensing units using OEM switch 1177594. Verify the fitting type and pressure setpoint match your original switch.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; ensure the system is not under recovery.
  2. Access — Remove the control/service panel to reach the switch and refrigerant line.
  3. Document — Photograph the wiring and switch location before disconnecting.
  4. Remove — Disconnect the leads and unthread the switch from its Schrader/access fitting (some applications require recovery).
  5. Install — Thread on the new switch, confirm the seal, and reconnect leads per your photo.
  6. Test — Restore power and confirm the unit completes a normal call without nuisance lockout.

Signs You Need a Replacement

  • System locks out on a low-pressure fault with a full charge
  • Compressor short-cycles on cold mornings
  • Switch will not reset or reads open at normal pressure
  • Visible corrosion or damage at the switch body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar T4H336GKD100 — 24V | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar T4H336GKD100 — 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar T4H336GKD100 — 24V | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online