Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Hot Surface Igniter/Sensor for T9MPV125L20A1 — Silicon Nitride HSI Kit | Ships Today
Tempstar

Tempstar Hot Surface Igniter/Sensor for T9MPV125L20A1 — Silicon Nitride HSI Kit | Ships Today

SKU: 1009524-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM hot surface igniter and flame sensor service kit (part number 1009524, "IGNITOR/SENSOR HSP SK") for the Tempstar T9MPV125L20A1 gas furnace. The hot surface igniter (HSI) is the component that glows white-hot to ignite the burner gas on each heating cycle, while the integrated sensor confirms flame presence so the control board keeps the gas valve open. This silicon-nitride style HSI is more durable than older silicon-carbide igniters and resists the cracking and thermal fatigue that cause no-heat calls. When the igniter fails, the furnace will typically run its inducer and blower but never light, leaving you with cold air or a lockout fault.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter / Sensor Service Kit (HSP)
Brand Tempstar (ICP / Heil family)
Element Silicon nitride hot surface igniter
Voltage 120V
Fit OEM direct replacement

Compatibility

Engineered as a direct-fit replacement for the Tempstar T9MPV125L20A1 variable-speed gas furnace. Because Tempstar, ICP, Heil, Comfortmaker and other International Comfort Products brands share furnace platforms, this igniter/sensor kit also services many sibling models in the same family. Always verify your existing part number against 1009524 before installing.

Installation Guide

  1. Safety First — Switch off the furnace at the disconnect and the breaker, then verify zero voltage at the control board with a multimeter. Shut off the gas supply.
  2. Access — Remove the lower burner-compartment service panel.
  3. Document — Photograph the igniter bracket, wire routing, and connector before disconnecting anything.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter from the burner assembly without touching the new element with bare fingers.
  5. Install — Seat the new igniter/sensor at the correct depth in the burner port, secure the bracket, and reconnect the harness exactly as photographed.
  6. Test — Restore gas and power, then run a heating cycle and confirm the igniter glows, the burner lights cleanly, and the flame holds without a flame-loss lockout.

Signs You Need a Replacement

  • Furnace runs the inducer and blower but the burners never ignite (no heat).
  • Visible cracks, white blistering, or breaks in the igniter element.
  • Igniter does not glow, or glows weakly, during the ignition sequence.
  • Control board flashes an ignition-failure or flame-sense lockout code.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar T9MPV125L20A1 — Silicon Nitride HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar T9MPV125L20A1 — Silicon Nitride HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar T9MPV125L20A1 — Silicon Nitride HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera