Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Hot Surface Igniter/Sensor for T8MPL125J20A1 — HSP Silicon Nitride | Ships Today
Tempstar

Tempstar Hot Surface Igniter/Sensor for T8MPL125J20A1 — HSP Silicon Nitride | Ships Today

SKU: 1009524-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter/sensor (part #1009524, HSP silicon-nitride type) lights the burners on your Tempstar T8MPL125J20A1 furnace and confirms flame presence. On a heat call the control board energizes the element until it glows hot enough to ignite gas; the same assembly helps verify the burner has lit. HSP silicon-nitride igniters are more rugged than older silicon-carbide elements but still fail from thermal cycling, cracking, or contamination. Telltale symptoms are the blower running with no heat, repeated ignition lockouts, a clicking gas valve that never lights, or a glow that is weak or absent.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter/Sensor (HSP, Silicon Nitride)
Brand Tempstar (ICP / Heil / Comfortmaker)
Function Burner Ignition / Flame Sensing
Application Gas Furnace

Compatibility

Direct OEM fit for the Tempstar T8MPL125J20A1 gas furnace and ICP-family equipment (Heil, Comfortmaker, Arcoaire, Keeprite) that specifies igniter/sensor 1009524. Confirm your existing igniter part number and connector style before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and confirm zero voltage with a multimeter.
  2. Access — Remove the burner-compartment access panel.
  3. Document — Photograph the igniter mounting position and wiring connector before disconnecting.
  4. Remove — Unplug the harness, remove the mounting screw(s), and carefully lift out the fragile element — never touch the new element with bare fingers.
  5. Install — Mount the new igniter/sensor in the same orientation, reconnect the harness, and confirm proper alignment over the burner.
  6. Test — Restore power, start a heat call, and confirm the element glows and the burners light promptly.

Signs You Need a Replacement

  • Blower runs but no heat is produced
  • Igniter does not glow or glows dim/uneven
  • Furnace locks out after repeated failed ignition attempts
  • Visible crack or break in the igniter element

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar T8MPL125J20A1 — HSP Silicon Nitride | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar T8MPL125J20A1 — HSP Silicon Nitride | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar T8MPL125J20A1 — HSP Silicon Nitride | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera