Overview

This OEM Tempstar hot surface igniter (part number 1009524, HSP SK) lights the burners on your TNE050B12A1 furnace. On a call for heat, the ignition control sends voltage to the igniter, which glows red-hot to ignite the gas as it leaves the burners. Hot surface igniters are brittle and degrade with every heating cycle — the silicon carbide element develops hairline cracks and high-resistance hot spots until it can no longer reach ignition temperature. The result is a furnace that clicks, drops out, and goes into lockout after several failed ignition attempts, often leaving you with no heat on the coldest days. Replacing an aged igniter restores reliable, on-demand ignition.

Specifications

Spec Value
OEM Part Number 1009524
Type Hot Surface Igniter (HSI), SK style
Function Igniter / Sensor (HSP)
Brand Tempstar (ICP / Heil family)
Element Silicon Carbide
Fitment OEM Direct Replacement

Compatibility

Direct-fit hot surface igniter for the Tempstar TNE050B12A1 furnace and related ICP, Heil, and Comfortmaker gas furnace platforms that use the SK-style HSI. Match the mounting bracket and connector to your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the element, align it to the burner, and reconnect the plug.
  6. Test — Restore power and watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace clicks but burners never light
  • System locks out after 3–4 failed ignition attempts
  • Igniter no longer glows or glows weakly/unevenly
  • Visible cracks or white spots on the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar TNE050B12A1 — Silicon Carbide HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar TNE050B12A1 — Silicon Carbide HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar TNE050B12A1 — Silicon Carbide HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online