The genuine OEM hot surface igniter (part #1009524, IGNITOR/SENSOR HSP) for the Tempstar TCK125N20A1 gas furnace. This silicon nitride hot surface igniter glows to roughly 2,500°F to ignite the gas at the burners on each call for heat, and on this platform it also serves the flame-proving sensing function. Hot surface igniters are the most common furnace heating failure: the brittle element cracks from thermal cycling, vibration, or being touched during service. A cracked igniter produces no glow, an open circuit, and a furnace that will not light.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter / Sensor (HSI)
Element Silicon nitride
Brand Tempstar (ICP / Heil)
Voltage 120V
Fit OEM exact replacement

Compatibility

Built for the Tempstar TCK125N20A1 and used across many ICP-family furnaces (Tempstar, Heil, Comfortmaker, Arcoaire). Match the mounting bracket and connector to your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully lift out the old igniter, handling it only by the ceramic base — never the element.
  5. Install — Set the new igniter in the exact factory position, secure the screw, and reconnect the plug. Do not touch the silicon nitride element with bare fingers.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace tries to start but burners never light (no glow)
  • Visible crack or break in the igniter element
  • Open circuit / no continuity across the igniter
  • Repeated ignition lockouts after several retries

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar TCK125N20A1 — Silicon Nitride | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar TCK125N20A1 — Silicon Nitride | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar TCK125N20A1 — Silicon Nitride | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online