Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Hot Surface Igniter for TCK075F14B1 — Silicon Nitride HSI | Ships Today
Tempstar

Tempstar Hot Surface Igniter for TCK075F14B1 — Silicon Nitride HSI | Ships Today

SKU: 1009524-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) — part number 1009524 (IGNITOR/SENSOR HSP SK) — is the ignition component for the Tempstar TCK075F14B1 gas furnace. On each call for heat, the control board energizes the igniter, which glows to roughly 2,000°F to ignite gas at the burners. The silicon-nitride element delivers faster and more durable ignition than older carbide igniters. When it fails, the furnace will not light and locks out after repeated trial-for-ignition attempts. Common symptoms include no heat, a furnace that clicks but never fires, and a cracked or no-longer-glowing element.

Specifications

Spec Value
Part Number 1009524
Description Ignitor/Sensor HSP Service Kit
Type Hot Surface Igniter
Brand Tempstar (ICP/Heil family)
Voltage 120V
Element Silicon Nitride
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM fit for the Tempstar TCK075F14B1 furnace and other ICP/Heil/Comfortmaker units that use the 1009524 ignitor/sensor service kit. Verify your existing part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas.
  2. Access — Remove the furnace burner/control access panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter harness and remove the mounting screw; handle the old igniter by the ceramic base only, never the element.
  5. Install — Mount the new igniter, confirm proper position over the burner, and reconnect the harness per your photo. Do not touch the new element with bare hands.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace will not ignite or produces no heat
  • Igniter no longer glows during the heat cycle
  • Visible cracks, chips, or breaks in the element
  • Repeated ignition lockouts or short-cycling on a call for heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar TCK075F14B1 — Silicon Nitride HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar TCK075F14B1 — Silicon Nitride HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar TCK075F14B1 — Silicon Nitride HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online