This is the OEM hot surface igniter (HSI) for the Tempstar T8MPV100J20B1 two-stage gas furnace. The igniter (OEM part 1172533) is a silicon-carbide element that energizes on a call for heat and glows red-hot to ignite gas at the burners. It is among the most common furnace failures because the element grows brittle with each cycle. This listing covers the igniter for the B1 revision of this model, which works alongside the 1172822 two-stage gas valve (Honeywell VR8205Q). Failure symptoms include the blower running with no flame, repeated ignition lockouts, no heat, and a cracked igniter element.
| Spec | Value |
|---|---|
| Part Number | 1172533 |
| Type | Hot Surface Igniter (HSI) |
| Brand | Tempstar / Heil / ICP |
| Element | Silicon Carbide |
| Voltage | 120V |
| Related Part | 1172822 (2-stage gas valve, VR8205Q) |
Fits the Tempstar T8MPV100J20B1 90%+ AFUE two-stage furnace and shared ICP/Heil platform variants using this igniter. Confirm against your unit's part list before ordering.