Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Hot Surface Igniter for T8DNL100L20A1 — OEM 1009524 | Ships Today
Tempstar

Tempstar Hot Surface Igniter for T8DNL100L20A1 — OEM 1009524 | Ships Today

SKU: 1009524-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter (part number 1009524, IGNITOR/SENSOR HSP SK) for the Tempstar T8DNL100L20A1 gas furnace. The hot surface igniter heats to a glowing temperature on each call for heat to light the burners, and it doubles as the flame-proving element on this platform. As the igniter ages it develops hairline cracks and high resistance, leading to delayed ignition, no ignition, or lockout after a few failed tries. Replacing a worn igniter is one of the most common no-heat fixes on these furnaces.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter / Sensor (HSP SK)
Brand Tempstar (ICP / Heil)
Fitment OEM
Application Furnace burner ignition
Function Ignition + flame sensing

Compatibility

Direct factory replacement for the Tempstar T8DNL100L20A1 furnace and used across many ICP-family furnaces sold under the Heil, Comfortmaker, and Tempstar brands. Match the connector and mounting bracket to your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness and unscrew the mounting bracket; handle the new igniter by the ceramic base only — never touch the silicon element.
  5. Install — Mount the new igniter, set the correct gap to the burner, and reconnect the harness per your photo.
  6. Test — Restore power and confirm the igniter glows and lights the burners on the next call for heat.

Signs You Need a Replacement

  • No glow when the furnace calls for heat.
  • Visible cracks or breaks in the igniter element.
  • Furnace locks out after several failed ignition attempts.
  • Delayed ignition with a noticeable gas smell or rollout.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Tempstar T8DNL100L20A1 — OEM 1009524 | Ships Today?
Yes. This is the factory-specified OEM igniter for the Tempstar T8DNL100L20A1 — OEM 1009524 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Tempstar T8DNL100L20A1 — OEM 1009524 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera