Overview

This genuine OEM high pressure switch (part number 1184656) protects the Tempstar TCA748GKA200 from dangerously high refrigerant discharge pressure. The switch is wired into the 24V control circuit and opens to shut down the compressor whenever system head pressure climbs above its trip point — a critical safety device that prevents compressor damage, refrigerant line rupture, and unsafe operating conditions. A failed or nuisance-tripping high pressure switch will cause the unit to short-cycle, lock out, or refuse to start, often misdiagnosed as a control board or contactor problem.

Specifications

Spec Value
Part Number 1184656
Type High Pressure Switch
Brand Tempstar
Function High-side safety cutout
Control Voltage 24V
Application Compressor protection

Compatibility

Direct-fit replacement for the Tempstar TCA748GKA200 condensing unit and shared across many ICP-family outdoor units (Heil, Comfortmaker, Arcoaire) using the same high-side safety control. Confirm the part number and connection style on your existing switch before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the control panel access cover to reach the switch and its terminals.
  3. Document — Photograph the two control wires and their terminal locations before disconnecting.
  4. Remove — Recover or pump down refrigerant as required, then disconnect the wires and unthread the old switch from its Schrader-style fitting on the high-side line.
  5. Install — Thread on the new switch with a fresh seal, reconnect the control wires per your photo, and leak-check the connection.
  6. Test — Restore power, start the system, and confirm the unit runs without nuisance tripping and that head pressure stays in range.

Signs You Need a Replacement

  • Compressor short-cycles or locks out on a high pressure fault.
  • Unit will not start even with normal pressures.
  • Switch shows open continuity when system pressure is normal.
  • Intermittent cooling with no clear airflow or charge issue.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar TCA748GKA200 — Auto-Reset | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar TCA748GKA200 — Auto-Reset | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar TCA748GKA200 — Auto-Reset | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online