Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar High Pressure Switch for TCA724GKA200 — OEM Safety Control | Ships Today
Tempstar

Tempstar High Pressure Switch for TCA724GKA200 — OEM Safety Control | Ships Today

SKU: 1184656-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM high pressure switch (part number 1184656) is the high-side refrigerant safety control for the Tempstar TCA724GKA200 condensing unit. Wired into the 24V control circuit, the switch continuously monitors discharge-side refrigerant pressure and opens the circuit to shut the compressor down if pressure climbs to an unsafe level. This protects the compressor and the rest of the sealed system from damage caused by a dirty condenser coil, a failed condenser fan, overcharge, or a restricted line. When the switch fails or sticks open, the unit may short cycle, refuse to start, or trip out on a high-pressure lockout even when system pressures are normal.

Specifications

Spec Value
Part Number 1184656
Type High Pressure Switch (High-Side Cutout)
Brand Tempstar (ICP / Heil)
Control Circuit 24 VAC
Function Opens on rising high-side pressure
Fits Model TCA724GKA200

Compatibility

This high pressure switch is the factory replacement for the Tempstar TCA724GKA200 and is used across many ICP-family condensing units and heat pumps, including matching Heil, Comfortmaker, and Day & Night outdoor sections that share this safety control. Confirm the part number and the connection type on your existing switch before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel to reach the switch and its harness.
  3. Document — Photograph the wiring and switch location before disconnecting.
  4. Remove — Disconnect the spade terminals. If the switch is brazed or threaded into the line, recover refrigerant first per EPA requirements before removing.
  5. Install — Fit the new switch, reconnect the control leads exactly as photographed, and evacuate/recharge if the sealed system was opened.
  6. Test — Restore power, start the unit, and confirm normal operation with no high-pressure lockout.

Signs You Need a Replacement

  • Unit trips on a high-pressure lockout even with a clean coil and proper charge.
  • Compressor short cycles or refuses to start.
  • Switch fails a continuity test when system pressures are within normal range.
  • Repeated nuisance cutouts during a cooling call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Tempstar TCA724GKA200 — OEM Safety Control | Ships Today?
Yes. This is the factory-specified OEM pressure switch for the Tempstar TCA724GKA200 — OEM Safety Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Tempstar TCA724GKA200 — OEM Safety Control | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online