Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Defrost Control Board for T4H442GKC200 — Heat Pump Defrost Board | Ships Today
Tempstar

Tempstar Defrost Control Board for T4H442GKC200 — Heat Pump Defrost Board | Ships Today

SKU: 1173636-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM defrost control board (part number 1173636) manages the defrost cycle on your Tempstar T4H442GKC200 heat pump. It monitors coil temperature and run time, then periodically reverses the system to melt frost off the outdoor coil before returning to heating. The board also coordinates the compressor, condenser fan, reversing valve, and auxiliary heat timing. When it fails, the outdoor coil ices over and chokes airflow, the unit gets stuck in or out of defrost, or the heat pump stops responding to calls entirely. Symptoms include a heavily frosted outdoor coil, no defrost cycle, continuous defrost, fan or compressor not energizing, or no output to the reversing valve.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar (ICP / Heil)
Function Defrost timing & outdoor unit control
Fit OEM Direct Replacement

Compatibility

Exact-fit OEM replacement for the Tempstar T4H442GKC200 and related ICP-family (Tempstar, Heil, Comfortmaker) heat pumps using the 1173636 defrost board. Confirm the board part number, connector layout, and defrost timing pin settings against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-area service panel to expose the defrost board.
  3. Document — Photograph every connector, plug, and the defrost-time jumper position before disconnecting.
  4. Remove — Unplug the harnesses, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, set the defrost timing pin to match the original, and reconnect each harness per your photo.
  6. Test — Restore power, run a heat call, and confirm normal operation and a proper defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over with no defrost cycle
  • Unit stuck running continuous defrost
  • Compressor or fan won't energize on a heat call
  • No 24V output to the reversing valve during defrost

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T4H442GKC200 — Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T4H442GKC200 — Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T4H442GKC200 — Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online