This genuine OEM defrost control board (part number 1173636) manages the defrost cycle on your Tempstar T4H436GKB200 heat pump. During cold-weather operation, frost accumulates on the outdoor coil and reduces heating efficiency. The defrost control board monitors coil temperature and run time, then commands a defrost cycle — reversing the refrigerant flow and energizing the auxiliary heat to clear ice from the coil. When this board fails, the unit may freeze over, stop heating, short-cycle, or run the defrost cycle continuously. A failed board is one of the most common causes of poor heat-pump performance in winter.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar (ICP / Heil)
Control Voltage 24V
Application Heat Pump Defrost Control
Fitment OEM Replacement

Compatibility

Engineered as a direct OEM replacement for the Tempstar T4H436GKB200 heat pump. This board is shared across multiple ICP-family heat pumps (Tempstar, Heil, Comfortmaker, Arcoaire) — confirm part number 1173636 matches the board currently installed in your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the outdoor unit's control-panel service cover.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Label and disconnect the low-voltage and sensor leads, release the board's mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new 1173636 board, reconnect each lead to the matching terminal per your photo, and seat the defrost sensor.
  6. Test — Restore power and initiate a test defrost (jumper the speed-up pins per the unit's wiring diagram) to confirm the reversing valve and aux heat energize.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never defrosts
  • Heat pump runs a defrost cycle constantly or at the wrong intervals
  • No heat output or frequent short-cycling in cold weather
  • Reversing valve or auxiliary heat fails to energize on call for defrost

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T4H436GKB200 — OEM 1173636 Heat Pump Board | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T4H436GKB200 — OEM 1173636 Heat Pump Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T4H436GKB200 — OEM 1173636 Heat Pump Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.