Overview

This OEM defrost control board (part 1173636) governs the defrost cycle on the Tempstar T4H360GKD400 heat pump. During heating operation, frost builds on the outdoor coil and chokes off airflow; the defrost board tracks elapsed time and coil temperature through the defrost sensor, then initiates a defrost — energizing the reversing valve, de-energizing the outdoor fan, and bringing on auxiliary heat so the indoor air stays warm while the coil clears. A failed defrost board is a leading cause of a heat pump that ices up solid, loses heating output, or runs costly emergency heat nonstop. Because the board orchestrates the reversing valve and fan relays, one failure can produce several symptoms at once.

Specifications

Spec Value
OEM Part Number 1173636
Type Defrost Control Board
Brand Tempstar (ICP / Heil)
Function Defrost timing, reversing valve & fan control
Application Heat Pump Outdoor Unit

Compatibility

Built for the Tempstar T4H360GKD400 heat pump and shared ICP/Heil/Comfortmaker platforms using the 1173636 defrost board. Match the part number and connector layout on your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the control compartment access panel.
  3. Document — Photograph every connector and wire on the existing board before disconnecting.
  4. Remove — Unplug each connector, release the standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board and transfer each connector to its matching terminal per your photo, including the defrost sensor lead.
  6. Test — Restore power and run a forced/test defrost to confirm the reversing valve, fan, and aux-heat outputs sequence correctly.

Signs You Need a Replacement

  • Outdoor coil ices over with no defrost cycle
  • Heat pump stuck on auxiliary/emergency heat
  • Defrost runs too frequently or never starts
  • Reversing valve or outdoor fan unresponsive during defrost

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T4H360GKD400 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T4H360GKD400 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T4H360GKD400 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.