Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Defrost Control Board for T4H336GKA200 — Heat Pump | Ships Today
Tempstar

Tempstar Defrost Control Board for T4H336GKA200 — Heat Pump | Ships Today

SKU: 1173636-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (Tempstar part 1173636) manages the defrost cycle on the T4H336GKA200 heat pump — monitoring the defrost thermostat and timer, energizing the reversing valve, and shutting off the outdoor fan to clear frost from the coil. A failed board causes a coil that ices over, a heat pump stuck in defrost, no reversing-valve action, or no outdoor unit operation at all. This is a direct OEM replacement matched to the original timing and relay logic.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar
Control Voltage 24V
Application Heat Pump Defrost Management
Fitment OEM Direct Replacement

Compatibility

Engineered for the Tempstar T4H336GKA200 heat pump and shared ICP / Heil / Comfortmaker platform units using OEM board 1173636. Verify the board's connector layout and timing pin options against your original.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser control panel to reach the board.
  3. Document — Photograph every plug, wire, and the defrost timing jumper position before disconnecting.
  4. Remove — Unplug the harnesses, note the timing pin setting, and unclip/unscrew the old board.
  5. Install — Mount the new board, set the defrost timing pin to match the original, and reconnect each harness per your photo.
  6. Test — Restore power and confirm normal heat-pump operation and a proper defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts
  • Heat pump gets stuck in defrost mode
  • No outdoor fan or reversing-valve action during heating
  • Board shows burnt traces, relay damage, or no output

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T4H336GKA200 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T4H336GKA200 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T4H336GKA200 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online