Tempstar

Tempstar Defrost Control Board for T4H324GKA200 — 24V Heat Pump | Ships Today

SKU: 1173636-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part #1173636) is the brain of the defrost cycle on your Tempstar T4H324GKA200 heat pump. It monitors the coil temperature sensor and accumulated run time, then commands the reversing valve and outdoor fan to clear frost from the outdoor coil during heating operation. The board manages 24V control logic, defrost timing intervals, and compressor/fan relay outputs. When it fails, the outdoor coil can ice over solid, heating capacity drops, and the system may short-cycle or lock out. Replacing a failed defrost board restores proper cold-weather heat pump performance.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar (OEM)
Control Voltage 24 VAC
Function Defrost timing, reversing-valve & fan control
Application Outdoor heat pump section

Compatibility

Direct OEM replacement for the Tempstar T4H324GKA200 heat pump. This board is common across the ICP family of heat pumps (Heil, Comfortmaker, Arcoaire, Keeprite) of the same generation. Verify the part number and terminal layout against your existing board before ordering.

Installation Guide

  1. Safety First — Kill power at the disconnect and breaker; verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the outdoor unit's control/electrical access panel.
  3. Document — Photograph every wire, plug, and terminal on the existing board before unplugging anything.
  4. Remove — Disconnect the low-voltage and line connections, release the mounting standoffs/screws, and lift out the old board.
  5. Install — Seat the new board on its standoffs and reconnect each lead exactly per your photo, matching defrost-sensor and reversing-valve terminals.
  6. Test — Restore power, initiate a defrost test (per the board's speed-up pins if equipped), and confirm the reversing valve shifts and the fan responds correctly.

Signs You Need a Replacement

  • Outdoor coil freezes over and never defrosts in heating mode
  • Heat pump short-cycles or won't enter/exit defrost
  • Reversing valve or outdoor fan won't respond on a call
  • Visible scorching, corrosion, or a burnt smell on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T4H324GKA200 — 24V Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T4H324GKA200 — 24V Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T4H324GKA200 — 24V Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online